Applications:
Clarification of low and medium viscosity fluids.
Micron rating:
50 to 1,000 µ, through a calibrated V-shaped media.
Service pressure:
10 bar standard
Capacity in m3/h:
up to 300 m3/h water.
Operating principle:
The fluid flows from inside to outside of the filter media. Dirt to be removed is collected on the inside
face of the filter element.
During cleaning the opening of the drain valve allows for parallel flowing of lose dirt removed from surface by rotating brushing scrappers
Information for Filter Design
POLE system (Only in French)see french section
Advantages:
High resistant filter media.
Brush or scrapper cleaning in addition to parallel flowing.
A comprehensive range of surface filters from 0.25 m2 to 1 m2, with flanges from DN 50 to 150.
Minimum required data for inquiry:
Type of fluid and application. Nominal and design flow capacity
Nominal and design pressure. Required micron rating.